首页 | 免费域名 | 个人服务器 | 一流信息监控拦截系统 | 虚拟主机知识库 | ASP 空间 | ASP技术大全 | 下载中心 | 客户服务中心
  7i24 > ASP技术大全 > 其它类文章 >
    7i24 .Com  
  远程关机脚本

7i24.Com不停为您服务
远程关机脚本

'来源:中文NT资源网(http://www.aboutnt.com)
'改写:沧海笑一声

'/\
'|| Remote Shutdown.vbs
'||
'|| Created by Harvey Hendricks, MCSE, A+,
'|| March 2001
'||
'|| email: hhendrks@aramco.com
'|| hhend@swbell.net
'||
'||
'|| Based on techniques and ideas from:
'|| SMS admin, SMS Installer, & WMI forums -> http://www.Swynk.com/discuss_home
'|| Win32 Scripting -> http://cwashington.netreach.net/
'|| Microsoft Windows Script Technologies -> http://msdn.microsoft.com/scripting
'|| Microsoft Online Library -> http://msdn.microsoft.com/library/default.asp
'|| Microsoft VBScript 5.5 documentation
'|| and Microsoft WMI SDK
'||
'||~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~
'|| SCRIPT LOGIC FLOW:
'|| Collects computername from user, calls function to ping the computername
'|| to determine if it is accessible, if not then display message and exit
'|| otherwise continue.
'|| Collects desired action to perform from the user, does error checking on
'|| the input to determine if it is acceptable, if not then display message
'|| and exit otherwise continue.
'|| Set variables and output messages based on the action chosen. Calls
'|| Win32Shutdown with the appropriate variable. Displays success message
'|| and exits
'||
'|| Uses WMI Win32Shutdown method from the Win32_OperatingSystem class
'|| to perform different logoff / powerdown / reboot functions
'||
'|| Testing found the following values to be effective on Win32Shutdown:
'|| Action decimal binary
'|| Logoff 0 0000
'|| Force Logoff 4 0100
'|| Reboot 2 0010
'|| Force Reboot 6 0110
'|| Powerdown 8 1000
'|| Force Powerdown 12 1100
'||
'|| Notice that the third bit from the right appears to be the "FORCE" bit.
'||
'|| A value of 1 will do a shutdown, ending at the "It is safe to turn
'|| off your computer" screen. I have no use for this and did not test it.
'||
'||
'||NOTES: - tested under Windows 2000 Pro. with ACPI compliant systems -
'|| SHOULD work under Windows NT4 without modification IF the
'|| system has compatible versions of WSH / WMI / VBscripting
'||
'||Logoff / Powerdown / Reboot:
'|| Does not work if a password protected screen saver is active or
'|| there is data to save. Either way the system waits for user input.
'||
'||Force Logoff / Force Powerdown / Force Reboot:
'|| Does not work if a password protected screen saver is active, will wait
'|| for user input. Otherwise will close open applications without saving data.
'||
'\/~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~


'/\/\/\/\/\/\/\/\/\/\/\/\/\/\ start function /\/\/\/\/\/\/\/\/\/\/\/\/\/\
'\/\/\/\/\/\/\/\/\/\/\/\/\/\/\______________/\/\/\/\/\/\/\/\/\/\/\/\/\/\/
function Ping(byval strName)
dim objFSO, objShell, objTempFile, objTS
dim sCommand, sReadLine
dim bReturn

set objShell = WScript.CreateObject("Wscript.Shell")
set objFSO = CreateObject("Scripting.FileSystemObject")

'Set default return value
bReturn = false

'Create command line to ping and save results to a temp file
sCommand = "cmd /c ping.exe -n 3 -w 1000 " & strName & " > temp.txt"

'Execute the command
objShell.run sCommand, 0, true

'Get the temp file
set objTempFile = objFSO.GetFile("temp.txt")
set objTS = objTempFile.OpenAsTextStream(1)

'Loop through the temp file to see if "reply from" is found,
'if it is then the ping was successful
do while objTs.AtEndOfStream <> true
sReadLine = objTs.ReadLine
if instr(lcase(sReadLine), "reply from") > 0 then
bReturn = true
exit do
end if
loop

'Close temp file and release objects
objTS.close
objTempFile.delete
set objTS = nothing
set objTempFile = nothing
set objShell = nothing
set objFSO = nothing

'Return value
Ping = bReturn
end function
'/\/\/\/\/\/\/\/\/\/\/\/\/\/\ end function /\/\/\/\/\/\/\/\/\/\/\/\/\/\
'\/\/\/\/\/\/\/\/\/\/\/\/\/\/\______________/\/\/\/\/\/\/\/\/\/\/\/\/\/\/



'/\/\/\/\/\/\/\/\/\/\/\ Start Main body of script /\/\/\/\/\/\/\/\/\/\/\/\
'\/\/\/\/\/\/\/\/\/\/\/\_________________________/\/\/\/\/\/\/\/\/\/\/\/\/
'Get computer name to operate on
ComputerName=InputBox("Enter the Machine name of the computer" & vbCRLF _
& "you wish to Shutdown / Reboot / Logoff", _
"Remote Shutdown / Reboot / Logoff", _
"ComputerName")

'if Cancel selected - exit
If (ComputerName = "") Then Wscript.Quit

'change the name to uppercase
ComputerName=UCase(ComputerName)

'ping the computername to see if it is accessible
bPingtest = ping(Computername)

If bPingtest = FALSE Then
y = msgbox ("'" & ComputerName & "' is not accessible!" & vbCRLF _
& "It may be offline or turned off." & vbCRLF _
& "Check the name for a typo." & vbCRLF, _
vbCritical, ComputerName & " NOT RESPONDING")
Wscript.Quit
end IF

'Get the action desired
Action=InputBox( _
"Select Action to perform on " & ComputerName & vbCRLF & vbCRLF _
& " 1 - Logoff" & vbCRLF _
& " 2 - Force Logoff ( NO SAVE )" & vbCRLF _
& " 3 - Powerdown" & vbCRLF _
& " 4 - Force Powerdown ( NO SAVE )" & vbCRLF _
& " 5 - Reboot" & vbCRLF _
& " 6 - Force Reboot ( NO SAVE )" & vbCRLF & vbCRLF _
& "NOTE:" & vbCRLF _
& " Using Force will close windows" & vbCRLF _
& " without saving changes!", _
"Select action to perform on " & ComputerName, "")

'if Cancel selected - exit
If (Action = "") Then Wscript.Quit

'error check input
If (INSTR("1234567",Action)=0) OR (Len(Action)>1) then
y = msgbox("Unacceptable input passed -- '" & Action & "'", _
vbOKOnly + vbCritical, "That was SOME bad input!")
Wscript.Quit
end if

' set flag to disallow action unless proper input is achieved, 1 => go 0 => nogo
flag = 0

'set variables according to computername and action
Select Case Action
Case 1 'Logoff
x = 0
strAction = "Logoff sent to " & ComputerName
flag = 1
Case 2 'Force Logoff
x = 4
strAction = "Force Logoff sent to " & ComputerName
flag = 1
Case 3 'Powerdown
x = 8
strAction = "Powerdown sent to " & ComputerName
flag = 1
Case 4 'Force Powerdown
x = 12
strAction = "Force Powerdown sent to " & ComputerName
flag = 1
Case 5 'Reboot
x = 2
strAction = "Reboot sent to " & ComputerName
flag = 1
Case 6 'Force Reboot
x = 6
strAction = "Force Reboot sent to " & ComputerName
flag = 1
Case 7 'Test dialog boxes
y = msgbox("Test complete", vbOKOnly + vbInformation, "Dialog Box Test Complete")
flag = 0
Case Else 'Default -- should never happen
y = msgbox("Error occurred in passing parameters." _
& vbCRLF & " Passed '" & Action & "'", _
vbOKOnly + vbCritical, "PARAMETER ERROR")
flag = 0
End Select

'check flag
' if equal 1 (TRUE) then perform Win32Shutdown action on remote PC
' and display a confirmation message
' if not equal 1 (FALSE) then skip the action and script ends
if flag then
Set OpSysSet=GetObject("winmgmts:{(Debug,RemoteShutdown)}//" _
& ComputerName & "/root/cimv2").ExecQuery( _
"Select * from Win32_OperatingSystem where Primary=true")
for each OpSys in OpSysSet
OpSys.Win32Shutdown(x)
y = msgbox(strAction,vbOKOnly + vbInformation,"Mission Accomplished")
next
end If

'Release objects
set OpSys = nothing
set OpSysSet = nothing


  2002年1月9日  阅读 2272 次  发送此页给朋友  来源:    版权争议  删除

相关文章:   近期热点:

上一篇: asp 函數介紹-1
下一篇: 在NT/2000中创建组
返回上一层...
搜索:

(C)2004-2022 7i24.Com 保留所有权利